Related industries
| Product Model | Primary-side rated current (Adc) | Primary-side overcurrent DC current (Adc) | Primary-side AC current overload value (Aac) | Electrical current ratio | DC accuracy (ppm) | AC accuracy (ppm) | Linearity (ppm) | Temperature stability (ppm/K) | Operating Voltage (V) | Power Supply Power (W) | Measurement aperture (mm) | Bandwidth (-3dB) (kHz) | Rated output current (A) | Zero-Offset Current (Full Temperature Range) (µA) | Measure resistance (Ω) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| CTM-2000D75 | ±2000 | 2400 | ±1700 | 125:1/250:1/500:1/750:1/1000:1/1250:1/1500:1/1750:1/2000:1 | 10 | 50 | 2 | 0.1 | 220 | 50 | 75 | 100 | ±1.0 | ±10 | 2 |
| CTM-5000D100 | ±5000 | 6000 | ±4250 | 5000:1 /2000:1/1000:1 | 20/50 | 50/100 | 2 | 0.1 | 220 | 150 | 100 | 100 | ±1.0/±0.5/±0.2/±0.1 | ±10 | 2 |
| CTM-10000D200 | ±10000 | 12000 | ±8500 | 5000:1 /2000:1/1000:1 | 20/50 | 50/100 | 2 | 0.1 | 220 | 250 | 200 | 100 | ±2.0 /0.4/0.2 | ±10 | 1 |