Products

High-precision current sensor development and manufacturing · A complete range for diverse applications

IVA converter

IV current-to-voltage converters can transform current signals into high-precision voltage signals. Depending on the accuracy of the converted voltage, they are classified as IVC converters, IVB converters, and IVA converters. The input terminal of the IVA converter can be directly connected to CTA-series current sensors.

  • Measurement range: 0.5A~2A
  • Operating bandwidth: 300kHZ
  • Output voltage: 5V/10V
  • Linearity: 5ppm
  • Supply voltage: ±15V/±24V
  • Note: Reverse amplification
Learn more

IVB converter

IV current-to-voltage converters can transform current signals into high-precision voltage signals. Depending on the accuracy of the converted voltage, they are classified as IVC converters, IVB converters, and IVA converters. The input terminals of IVB converters can be directly connected to CTB, CTW, and CTF series current sensors.

  • Measurement range: 0.1mA~5A
  • Operating bandwidth: 300kHZ
  • Output voltage: 5V/10V
  • Linearity: 5ppm
  • Supply voltage: ±15V/±24V
  • Note: Inverting amplifier
Learn more

IVC converter

IV current-to-voltage converters can transform current signals into high-precision voltage signals. Depending on the accuracy of the converted voltage, they are classified as IVC converters, IVB converters, and IVA converters. The input terminals of IVC converters can be directly connected to CTC, CTD, and CTG series current sensors.

  • Measurement range: 1uA~5A
  • Operating bandwidth: 100kHZ
  • Output voltage: 5V/10V
  • Linearity: 50ppm
  • Supply voltage: ±15V/±24V
  • Note: Inverting amplifier
Learn more

IPLC converter

Converts bipolar current signals into high-precision 4~20mA signals and can also be used independently.

  • Measurement range: 40mA~1A
  • Operating bandwidth: 100kHZ
  • Linearity: 50ppm
  • Supply voltage: ±15V/±24V
Learn more

IRMS converter

Converts DC or AC current signals to high-precision DC voltage signals using RMS measurement; can also be used independently.

  • Measurement range: 40mA~2A
  • Operating bandwidth: 10kHZ
  • Linearity: 500ppm
  • Supply voltage: ±15V/±24V
Learn more

IRMS+PLC Converter

It converts the input DC or AC current signal into a high-precision 4~20mA current output signal using the RMS method, and can also be used independently.

  • Measurement range: 50mA~1A
  • Operating bandwidth: 10kHZ
  • Linearity: 500ppm
  • Supply voltage: ±15V/±24V
Learn more