Industry News

Analysis of Challenges in AC and DC Voltage Measurement: How to Ensure Stability Across a Wide Temperature Range

Engineers working on energy storage PCS, new-energy vehicle three-electric systems, industrial power supplies, and mobile testing equipment have mostly encountered a tricky problem: voltage sensors that calibrate perfectly at room temperature in the lab start to show erratic readings as soon as they are taken to field conditions with high or low temperatures.

exhibits DC zero drift and steady-state reading deviation at low temperatures; at high temperatures, waveform amplitude and phase shift occur, leading to distortion in harmonic and transient tests; repeated diurnal temperature variations cause data failure mid-test. Many engineers spent considerable time troubleshooting wiring and data acquisition units only to discover that the issue stemmed from the wide-temperature stability of the voltage sensors . Choosing an experienced voltage sensor manufacturer and understanding the underlying design logic can help avoid such field challenges.

AC/DC voltage acquisition itself is more difficult to handle than single-phase AC or DC measurement. It requires simultaneously capturing the DC steady-state component and wideband AC signals; throughout the entire sampling chain, parameters at multiple stages vary with temperature, and errors accumulate across stages.

The voltage divider resistor changes its resistance with temperature, causing a shift in the voltage division ratio; conditioning and isolation devices exhibit zero-point temperature drift; variations in insulating medium parameters interfere with high-frequency signals; and structural stress resulting from sudden temperature changes also introduces additional errors. With multiple errors compounding, even the best-calibrated parameters can easily yield inaccurate measurements on-site if only room-temperature calibration is performed. Experienced voltage sensor manufacturers do not limit themselves to room-temperature specifications but implement layered control across the entire signal chain to address various field risks.

600.jpg

I. Front-end Voltage Divider Network: Reduces Temperature Drift at the Source

The voltage divider is the signal input and also the primary source of temperature drift.

Many solutions focus only on voltage rating and resistance value, neglecting the matching of resistor temperature coefficients between the high- and low-voltage sides. Once the two have inconsistent temperature coefficients, the voltage division ratio will shift with temperature changes. A practical approach is to select resistor networks with matched temperature coefficients, so that the resistance variations in the high- and low-voltage branches offset each other, reducing the overall temperature sensitivity of the voltage division ratio.

must also be paired with equipotential shielding design. The stray distributed capacitance on the high-voltage side changes under high and low temperatures, easily causing phase shifts in high-frequency AC signals; in pulse and harmonic test scenarios, this deviation directly affects waveform analysis results. Experienced voltage sensor manufacturers simultaneously consider both insulation reliability and wide-temperature consistency of stray parameters during the voltage division design stage.

II. Isolation and Signal Conditioning: Focus on Controlling Hidden Drift Caused by Self-Heating

AC and DC measurements commonly use two technical approaches, each suited to different operating conditions. The fluxgate solution exhibits stable zero-point characteristics in the DC and low-frequency ranges, making it suitable for long-term DC voltage monitoring; for high-frequency dynamic signals, a conditioning path with matched bandwidth is required.

When selecting , don't just look at room-temperature parameters; pay close attention to the temperature coefficients of offset voltage and bias current. Much drift isn't caused by ambient temperature but by self-heating in the chip, which creates local temperature differences. This self-heating, combined with environmental changes, gradually shifts the zero point.

In terms of hardware layout, heat-generating components and precision sampling areas should be kept separate. Professional voltage sensor manufacturers use thermal simulation during the early design phase to plan the layout and proactively avoid errors caused by self-heating.

III. Multipoint Temperature Compensation: Addressing the Nonlinear Characteristics of Temperature Drift

Even the best components have inherent temperature drift, so compensation is a necessary fail-safe measure.

Many early solutions only采集ambient air temperature and use a single linear formula to correct errors. However, actual testing reveals that the temperature drift curve is not a straight line;拐点often appear in the low-temperature and high-temperature ranges, causing simple linear compensation to significantly amplify errors at both ends of the full temperature range.

A solution more aligned with test conditions: temperature measurement points are placed close to the sampling and isolation core components to acquire the sensor body temperature rather than the ambient temperature; multi-point calibration is performed in high- and low-temperature chambers, separately fitting the temperature variation characteristics of the DC zero point and gain, as well as the AC amplitude and phase; each product is programmed with independent parameters and uses piecewise compensation, without sharing a unified compensation coefficient. Fine-grained calibration is an important technical step in the development process of voltage sensors

IV. Package Structure Design: Addressing Stress Impact from Rapid Temperature Changes

Constant high or low temperatures are still manageable, but rapid temperature changes pose a greater challenge on-site. Vehicle testing, outdoor power stations, and high/low temperature cycling aging rigs often experience temperature differences of several dozen degrees within a short period.

The housing, potting compound, PCB substrate, and metal terminals have different coefficients of thermal expansion. When the temperature changes abruptly, mechanical stress is generated; this stress transfers to precision resistors and chips, causing additional drift. This is a hidden source of error that many engineers overlook even after extensive troubleshooting.

The optimization approach prioritizes potting materials with low stress, low shrinkage, and stable wide-temperature characteristics, balancing insulation capability with uniform thermal conductivity; stress-relief structures are added at the terminals and lead-out positions to reduce deformation effects caused by repeated thermal cycling.

5. System Level: Stable voltage sensors do not necessarily mean the entire data acquisition chain is stable

This is a point that is easily overlooked during field debugging: even if the voltage sensor specifications are qualified, the high-voltage leads, connectors, and the input impedance of the data acquisition card will all vary with temperature, causing errors to compound.

For high-precision testing of , it is recommended to perform high- and low-temperature verification and joint calibration on the entire link; after power-up, allow for a warm-up period and collect data only after the sensor's internal temperature has stabilized. When selecting components, you can also consult with the voltage sensor manufacturer regarding comprehensive test support for the entire measurement system.

last

The stability of the voltage sensor in wide-temperature environments, , is essentially a comprehensive end-to-end error management approach.

suppresses temperature drift at the source through a voltage divider architecture, controls self-heating in the conditioning stage, corrects nonlinear deviations via multi-point segmented compensation, and then withstands mechanical stress caused by thermal shock through structural design. For engineers, selecting a voltage sensor is not merely choosing a component; it is choosing a measurement solution validated under actual operating conditions. A reliable voltage sensor manufacturer will address on-site challenges such as high and low temperatures and rapid temperature changes during R&D and calibration, ensuring that AC and DC voltage data remain consistently trustworthy across various test scenarios in energy storage, the three-electric system, and industrial power supplies.